13,000 m²
Cold Storage Facility Rehabilitation
Sadat City, Menoufia · Egyptian National Company
Main renovation contractor: MEP, refrigeration, fire systems, epoxy floors, 60 cold rooms
Contact Us
Cairo Head Office
Riyadh Office

MEP & systems integration
Electrical, mechanical, plumbing, HVAC and low-current systems designed with the architecture and interiors, then installed, tested and handed over inside one accountable contract.
MEP works decide how a building performs long after the finishes stop being new: whether rooms cool evenly, whether power holds under load, whether a fire is detected in time. At NoVi, MEP and systems integration is one of six core capabilities, coordinated with the architecture from the first layout rather than added afterwards.
The clearest proof is the cold storage facility rehabilitation in Sadat City: 13,000 m² and 60 cold rooms, where we are the main renovation contractor for plumbing, electrical, fire alarm and firefighting, refrigeration and roof insulation. MEP integration is also in our scope on Lina Farm workers accommodation in Minya and The Marquee in Taj City, New Cairo.
Project proof
Figures, roles and status from NoVi's 2026 corporate portfolio. Images are original visualisations inspired by each project, not site photographs.

13,000 m²
Sadat City, Menoufia · Egyptian National Company
Main renovation contractor: MEP, refrigeration, fire systems, epoxy floors, 60 cold rooms

≈ 4,675 m²
Taj City, New Cairo · Madinet Masr
Design & build: architecture, steel structure, MEP, façade, FF&E coordination

Taj City, New Cairo · Madinet Masr
Integrated design & build: architecture, fit-out, MEP, FF&E, courtyard and pool

01MEP & Systems
Cooling loads room by room; split, ducted, VRF or chilled-water options; fresh air and extract routed with the ceiling design.
Load schedules, distribution boards, cable sizing, earthing, and sockets and switches drawn against the furniture plan.
Hot and cold water, pumps and heaters, drainage falls and venting, coordinated with waterproofing in every wet area.
Detection, alarm, sprinklers and extinguishers, with escape routes and signage designed to the applicable code.
Data and Wi-Fi, CCTV, intercom and access control, audio, and the containment that lets a smart home follow later.
Cold rooms, cold-room doors and insulated envelopes for industrial and food facilities, integrated with power and fire systems.

02MEP & Systems
Most budget overruns in a finished interior trace back to services: a duct that will not fit the ceiling void, a drain without enough fall, a board sized for yesterday's load. We draw combined services layouts over the architectural and interior design plans, so ducts, pipes and cable trays are resolved before a single wall is closed.
03MEP & Systems
04MEP & Systems
Available electrical capacity, water and drainage points, the existing fire system and what the landlord or developer allows to change.
Cooling and electrical loads calculated, equipment selected and layouts drawn over the interior plan.
Clashes resolved in shop drawings, and every MEP item listed with quantities in the BOQ rather than hidden in a lump sum.
Rough-in inspected before it is covered, under our ISO 9001 QA/QC and site safety procedures.
Pressure tests and commissioning, then as-built drawings, test records and equipment documents at handover.
05MEP & Systems
In Egypt, the limits are usually the unit's supplied capacity, compound rules on condenser positions and façade openings, and the drainage the developer provided, whether in New Cairo, Sheikh Zayed or the New Administrative Capital. See fit-out in Egypt.
In Saudi Arabia, systems follow Saudi Building Code requirements, and fire and evacuation design is prepared for Civil Defense review with the licensed office that submits it. See fit-out in Riyadh, or book a site survey.
06MEP & Systems






From the portfolio
Real photography from our project galleries.
Questions
Straight answers to what clients ask us before a site survey. Not covered here? Ask the team directly.
Ask the teamAir conditioning and ventilation, electrical power and lighting circuits, water supply and drainage, fire alarm and firefighting, and light-current systems such as data, CCTV, intercom and access control. In industrial projects it can also cover refrigeration and cold rooms.
Both. We install, test and commission MEP inside our fit-out, renovation and design and build contracts. You can also hire us for MEP design only and receive loads, layouts and quantities your own contractor can price.
Yes. We calculate each room's load, compare ducted, VRF and central options on layout and running cost, and place diffusers and outdoor units with the ceiling and façade design.
We design the fire alarm and firefighting layouts to the applicable code and prepare the approval package. Where the authority requires a licensed office to stamp and submit it, we coordinate the submission with that office.
Yes. We check incoming capacity and the condition of boards, piping and AC, replace what has aged, add missing light current, and test everything before new finishes cover it. See renovation.
Yes. Our largest MEP-led scope is the 13,000 m² cold storage rehabilitation in Sadat City, covering electrical, plumbing, fire systems, refrigeration and 60 cold rooms. See industrial facilities.
Start a project
Tell us the building type, area and what the base building provides. An engineer from Cairo or Riyadh will propose the MEP scope and a survey date.